If the thermostat says AUX or EM Heat and the PECO statement just jumped, the outdoor unit is no longer doing the real work. The backup heater is.
AUX or EM Heat stuck on and the bill climbing?
That is backup electric heat carrying your house, not your heat pump. Get the system diagnosed before another PECO cycle.
What auxiliary heat and emergency heat actually are
A heat pump does not make heat the way a toaster does. It moves heat from outdoor air into the house. That is why a working heat pump can deliver two to four units of heat for every unit of electricity it uses. An electric resistance coil, the backup strips in most air handlers, delivers one unit of heat for every unit of electricity. Same comfort. Three times the bill, or worse.
Auxiliary heat (AUX on the thermostat) turns on automatically. The heat pump is still trying. The indoor strips or a paired furnace add extra heat because the outdoor unit cannot keep up with the setpoint. That is normal on a standard system when it is below freezing, during a defrost cycle, or when someone raises the thermostat several degrees at once.
Emergency heat (EM Heat) is a manual setting. It shuts the outdoor unit off and runs only the backup. Use it when the outdoor unit is dead, iced beyond a normal defrost, or a technician told you to. Leaving EM Heat on all January is how an all-electric house burns four figures on one winter bill.
How a regular heat pump behaves
On a conventional single-stage or two-stage heat pump, capacity falls hard as the outdoor temperature drops through the 30s. Below freezing, many of these units are already leaning on backup. By the teens, a normal design-night range across Montgomery County, Philadelphia, Bucks County, Chester County, and Delaware County, the compressor is doing a fraction of the work and the strips or furnace are carrying the house. The AUX light is not a fault code. It is the system admitting the outdoor unit has run out of cheap heat.
How a high-end inverter and cold-climate system behaves
A variable-speed inverter compressor can spin faster when the air is thin and cold. A cold-climate heat pump is built to keep extracting heat well below freezing, often holding most of its rated capacity into the single digits, with usable output below zero. Auxiliary heat still exists as a safety net. It should not be the nightly plan. On a well-set system you may see AUX for a few minutes during defrost or a big morning recovery. You should not see it locked on at 38°F.
Every house is wired and programmed a little differently. Balance points, lockouts, and dual-fuel changeover are set at install. If AUX runs constantly in mild weather, or the house will not hold setpoint, do not guess at the thermostat. Have the system diagnosed, starting with the original installer or a shop that actually works your brand.
If the unit is down today, that is a heat pump repair call, not an equipment lecture.
Why the electric bill explodes when backup heat takes over
Heat-pump mode is cheap heat. Strip mode is an electric furnace wearing a heat-pump costume. On PECO rates, a house that lives on backup for a cold week can add hundreds of dollars. A full month of strips carrying an older or undersized system is how some homeowners see a winter bill they do not recognize, sometimes crossing into four figures.
That is not “the heat pump is inefficient.” That is the heat pump having left the building. The compressor is the efficient machine. The coil in the air handler is a space heater. If winters stay sharp, paying for a system that remains in heat-pump mode at 10°F or 5°F is not a luxury feature. It is the difference between moving heat and manufacturing it.
A higher first cost on a cold-climate or high-efficiency inverter system pays back in the winters where a standard unit would have handed the load to strips. The payback is fastest in leaky or all-electric homes, and in houses that already watch AUX light up every time the forecast dips below freezing.
Three ways Greater Philly homes heat with a heat pump now
EMCO Tech is a Carrier preferred dealer serving Montgomery County, Philadelphia, Bucks County, Chester County, and Delaware County. The Carrier residential lineup is the frame we use with homeowners: a straightforward system that needs backup sooner, a premium communicating system built for deep cold, and a high-efficiency inverter crossover that puts serious low-ambient heating on the ductwork you already have, without the full premium-tier price.
1. Standard-efficiency heat pumps
Single-stage or two-stage outdoor units. Fine in October and April. They lose a large share of heating capacity as outdoor air falls through freezing. Backup, electric strips or a gas furnace in a dual-fuel setup, is not a rare event. It is the January plan. Upfront cost is the lowest of the three. Operating cost on the coldest mornings is the highest if the backup is electric.
Best fit: milder winters, dual-fuel with a healthy gas furnace, or a house where first cost has to win.
Watch-out: AUX that starts in the mid-30s and stays on. That is a PECO problem, not a comfort badge.
2. Premium cold-climate systems
Variable-speed inverter compressors, matched indoor equipment, and controls that actually talk to each other. Carrier’s Infinity line with Greenspeed intelligence is the example we install when the homeowner wants the outdoor unit to keep working in heat-pump mode deep into a Delaware Valley cold snap, published heating well below zero on the right model, not a marketing footnote.
You pay more on day one because the indoor coil or furnace, the thermostat, and the outdoor unit are a matched system. You buy back that money on the nights a standard unit would have been a strip heater. Quiet, steady supply air. Fewer on and off swings. Aux heat as a last resort, not a lifestyle.
Best fit: all-electric homes, older houses that already punish a weak outdoor unit, anyone who is tired of watching AUX.
The catch: it is the top of the ladder. It is worth it when the bill and the comfort both justify the match.
3. The crossover: high-efficiency inverter, side-discharge, on your existing ducts
This is the option most quotes still skip. A compact side-discharge outdoor unit, the slim cabinet people associate with ductless, can be piped to a conventional air handler or furnace and push heat through the vents you already have.
Those outdoor units use the same family of hyper-inverter technology that keeps a ductless head heating when it is ugly outside. You get low-ambient capacity and a quiet cabinet without buying a full premium communicating indoor suite. The indoor side can stay a standard air handler or a regular furnace in dual-fuel. That is how you get cold-weather inverter performance without the Infinity price tag.
Best fit: a house with decent ducts, a furnace or air handler that still has life, and a homeowner who wants sub-freezing heat-pump mode without a full premium swap.
Not a loophole: it still has to be sized, charged, and controlled correctly. A pretty outdoor cabinet on the wrong indoor coil is just a pretty outdoor cabinet.
Which of the three belongs in your house
There is no single right answer for every rowhome in Fishtown and every colonial in Horsham. Ducts, electrical service, existing furnace, and how hard the house leaks all change the math. What does not change: if AUX is a habit above the mid-30s, you are paying electric-heater prices for heat-pump comfort. That is the upgrade conversation.
What a planned upgrade looks like here
We work from 2424 Wyandotte Rd in Willow Grove and 7934 State Rd in Philadelphia. A heat pump installation visit is a load look at the house, not a model number first. Cold-climate ducted, dual-fuel with the furnace you have, or a side-discharge inverter on existing ducts. Then a written quote, current incentives we can document, and a schedule that does not wait for the outdoor unit to die on a Tuesday night.
If the system is already in the last third of its life, read planning a heat pump replacement before you buy another compressor for a 14-year-old box. If you want the equipment family in one place, start with Carrier residential HVAC systems.
Two maintenance visits a year keep defrost, charge, and airflow honest. That is how an inverter system stays in heat-pump mode instead of quietly sliding back onto strips.
Quick answers
No. AUX is automatic help while the heat pump still runs. Emergency heat is a manual override that turns the outdoor unit off. One is normal in real cold. The other is a temporary bridge when the outdoor unit should not run.
A heat pump changes temperature slowly. A jump of several degrees looks like a rush job to the control board, so it calls backup to catch up. Set it and leave it. Large setbacks are how people train a system to waste electricity.
Yes. A standard unit can still run. It just makes less heat, so backup fills the gap. An inverter cold-climate unit is built to keep that gap small, which is the entire point of paying more for the outdoor unit.
In heat-pump mode, yes, by a wide margin. The day the strips take over, you are paying electric-heat prices. The upgrade is not that heat pumps are magic. The upgrade is staying in heat-pump mode longer.
If the AUX light is the reason you opened this
Short burst on a single-digit night: expected. AUX locked on during a 40-degree afternoon, or a bill that no longer looks like last winter’s: get the system looked at. Sometimes it is a dirty coil, a tired charge, or a lockout set too high. Sometimes the outdoor unit is simply the wrong machine for how cold this region actually gets.
Call 215-366-1001, book online, or use the contact form. Tell us the age of the outdoor unit and whether AUX or EM Heat has become a habit. We will tell you whether this is a setting, a repair, or a different class of heat pump.
Serving Montgomery County, Philadelphia, Bucks County, Chester County, and Delaware County, from Willow Grove to West Chester and everywhere in between.
Stop paying strip-heat prices
AUX stuck on now
Fast diagnosis on a unit that is leaning on backup or iced up. We work your brand.
Upgrade to cold-climate
A load look, a written quote, and incentives we can document. Standard, premium, or crossover inverter.
Book online
Pick a time that does not wait for the outdoor unit to die on a Tuesday night. Or call 215-366-1001.
Latest Updates – Keep Cool, Feel Warm, Breathe Clean Air with EMCO Tech
Planning a Heat Pump Replacement: Upgrade Before It Fails
The worst time to replace a heat pump is the morning it dies. A planned swap lets you choose the equipment, lock in better pricing, and stay warm on…
Weatherizing Your Home Before Winter (The Cheap Fixes That Make Your Furnace’s Job Easier)
Before you blame the furnace for a cold house, check the holes it is fighting. Most homes leak a surprising amount of heat through gaps you never…